Ana içeriğe geç

NGS-360-3 — electrical design (internal)

Internal

Covisart internal engineering documentation. Not for distribution to customers or third parties.

Source of truth: the NGS_ElectricalSchema repository (BOM .xlsx, SLD-001, Harness Design Package). These pages summarize the current state; when they disagree with the repo, the repo wins.

System summary

ParameterValue
Supply45 kW, 380 V AC, 3-phase + N + PE, 50/60 Hz (TN-S — to be confirmed per site)
Main incomerQ1 Schneider TeSys GV3P73 MPCB, set 67–70 A (LOTO isolation point)
Axis 1 — PITCHBeckhoff AX5125 (25 A) + AM8073, stationary cabinet
Axis 2 — YAWBeckhoff AX5118 (18 A) + AM8063, on rotating yaw stage
Axis 3 — ROLLBeckhoff AX5118 (18 A) + AM8063, on rotating roll stage
SafetyAX5801-0000 STO card in all three drives, dual-channel from cabinet safety relay -K1
Power transmission3× through-bore power slip rings, 6 ch × 35 A
Data transmission3× capsule data slip rings (EtherCAT + STO)
Control power3× 24 V / 10 A PSUs, one per drive location
BrakingAX2090-BW51-1000 external resistor per drive (DC-links not shared)
EMCAX2090-NF50 mains filter(s), EN 61800-3 Class C2
FieldbusEtherCAT daisy-chain: master → pitch → yaw → roll

Document register

DocTitleCurrent rev
BOMComponent listRev 5 (Schneider migration) — .xlsx is source, PDF generated
SLD-001Single-line diagramRev 5
HN-001 / CS-001 / CT-001Harness, cable schedule, terminal tablesHarness package (CT-001 rebuilt for Schneider terminal marking)
SR-001Slip ring allocationRev A
LB-001Labeling planRev A
RT-001Routing / segregation / EMCRev A
TC-001Test checklistRev B
LY-001 / LY-002Cabinet / stage enclosure layoutsRev D / Rev B
WD-001Safety schematicRev A

Sections