Site requirements

The following requirements must be met on site before the system is delivered.

Power supply

RequirementValue
Mains3 phases + Neutral + PE, 380/400 V AC, 50/60 Hz
Earthing systemTN-S (separate neutral and protective conductor)
Connected load45 kW
Supply cable5-core (3L + N + PE), sized in accordance with local regulations
Neutral conductor is mandatory

The control circuit supply is taken phase-to-neutral (~230 V). The system cannot be commissioned on a site supply without a neutral conductor.

  • For sites exposed to lightning risk (supplied via overhead lines or open structures), the surge protection class will be determined jointly during the project phase.
  • The prospective short-circuit current of the supply must be reported to Covisart before installation.

Environment

RequirementValue
Ambient temperature−10 °C … +45 °C
Motion areaMotion area given on the model page + safety clearance

Floor

  • The base frame is anchored to the floor by means of integrated floor mounting plates.
  • The floor must be suitable for the unit weight and the dynamic loads.

Network

  • Ethernet connection between the host computer and the motion computer.
  • Internet access, if the remote support service is required.